HE3Z48-1

Circuit Breakers

CIRCUIT BREAKER

HE3Z48-1

5925-01-044-3041

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.330 inches nominal

  • Iii Nonturn Device Radius

    0.610 inches minimum and 0.640 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Special Handling Feature

    magnetic

  • Features Provided

    high inrush protection

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Frequency In Hertz

    60.0 all locations

  • Body Length

    1.562 inches maximum

  • Body Width

    1.875 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Iii Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Iii Nonturn Device Diameter

    0.235 inches minimum and 0.265 inches maximum

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and 20.000 maximum at 200 pct all locations

  • Iii Unpackaged Unit Weight

    5.400 ounces

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...