52485-2
Switches
SWITCH,PRESSURE
52485-2
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 165.0 deg fahrenheit maximum
-
Overall Length
3.171 inches nominal
-
Contact Adjustment Type
external deactuation point screw and external actuation point screw
-
Contact Load Current Rating
15.0 amperes resistive load first voltage
-
Nominal Thread Size
0.125 inches single pressure connection
-
Media For Which Designed
gas
-
Contact Adjustment Range
+0.15/+4.00 actuation point inches of water and +0.15/+4.00 deactuation point inches of water
-
Thread Series Designator
npt all pressure connection
-
Thread Series Designator
unf all threaded hole
-
Terminal Type
screw
-
Contact Load Current Rating
250.0 milliamperes resistive load third voltage
-
Mounting Method
base and threaded hole
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Nominal Thread Size
0.190 inches all threaded hole
-
Pressure Connector Type
plain, threaded internal all connections
-
Features Provided
electrical access port
-
Pressure Switch Type
differential
-
Overall Diameter
3.125 inches nominal
-
Contact Voltage Rating In Volts
480.0 ac at sea level first voltage
-
Contact Voltage Rating In Volts
250.0 dc at sea level third voltage
-
Contact Load Current Rating
500.0 milliamperes resistive load second voltage
-
Contact Action Stimulus
increase
-
Contact Voltage Rating In Volts
125.0 dc at sea level second voltage
-
Contact Adjustability
deactuation point adjustable and actuation point adjustable
-
Thread Quantity Per Inch
32 all threaded hole