Technical Characteristics

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.140 minimum at 200 pct single location and 0.750 maximum at 200 pct

  • Body Style

    12a single pole type

  • Mounting Slot Width

    0.218 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.490 inches minimum and 3.510 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.209 inches minimum and 0.229 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Body Length

    5.790 inches minimum and 5.810 inches maximum

  • Body Width

    1.016 inches minimum and 1.036 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Mounting Surface To Terminal End Distance

    3.115 inches minimum and 3.135 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole and 2 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.138 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...