Technical Characteristics

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 ac and 3000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    1.937 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac and 25.0 amperes dc all locations

  • Trip Release Characteristic

    time delay all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Frequency In Hertz

    400.0

  • Test Data Document

    18876-11041214 drawing

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...