50-218-1-MG3

Circuit Breakers

CIRCUIT BREAKER

50-218-1-MG3

5925-01-047-1608

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.980 inches minimum and 1.000 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.053 inches minimum and 3.073 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Unpackaged Unit Weight

    9.750 ounces

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Body Style

    12a single pole type

  • Body Length

    3.709 inches minimum and 3.729 inches maximum

  • Boss Height

    0.146 inches minimum and 0.166 inches maximum

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Trip Release Method

    thermal single location

  • Trip Release Characteristic

    instantaneous single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...