MIL-PRF-39019/1
Circuit Breakers
CIRCUIT BREAKER
MIL-PRF-39019/1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Body Length
1.531 inches minimum and 1.562 inches maximum
-
Specification/Standard Data
81349-mil-c-39019/1 government specification
-
Circuit Protection Type
overcurrent single location
-
Body Width
0.594 inches minimum and 0.625 inches maximum
-
Pole Quantity
1
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Mounting Surface To Terminal End Distance
1.669 inches minimum and 1.700 inches maximum
-
Thread Series Designator
unef
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct single location
-
Unpackaged Unit Weight
50.0 grams
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location and 500.0 dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location and 50.0 dc single location
-
Trip Release Method
magnetic single location
-
Terminal Type And Quantity
2 wire hook
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.906 inches maximum
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
-
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location and 4.0 amperes dc single location