4SE00075-3

Circuit Breakers

CIRCUIT BREAKER

4SE00075-3

5925-01-047-4689

5925 - Circuit Breakers

Naval Air Warfare Center Aircraft

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Arc Quenching Method

    magnetic blowout

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Body Width

    0.990 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct single location and 8.000 maximum at 200 pct single location

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Pole Quantity

    1

  • Unpackaged Unit Weight

    0.690 pounds

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Boss Height

    0.156 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Actuator Position Designation

    at pole one

  • Body Length

    3.719 inches nominal

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Actuator Function

    trip-reset

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...