HB2Z1-97
Circuit Breakers
CIRCUIT BREAKER
HB2Z1-97
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
type data on certain environmental and performa
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Specification/Standard Data
81349-mil-prf-39019/3 government specification
-
Body Length
1.562 inches maximum
-
Unpackaged Unit Weight
100.0 grams
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Body Width
1.281 inches maximum
-
Test Data Document
81349-mil-prf-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general
-
Actuator Position Designation
between pole one and two
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Body Style
multipole-single actuator type
-
Terminal Type And Quantity
4 wire hook
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac all locations and 6.0 amperes dc all locations
-
Trip Release Method
magnetic all locations
-
Thread Quantity Per Inch
32
-
Nominal Thread Size
0.375 inches
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 50.0 dc all locations
-
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations and 500.0 dc all locations
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
-
Reset Method
manual
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Special Handling Feature
magnetic
-
Fragility Factor
moderately rugged