2131850-22

Circuit Breakers

CIRCUIT BREAKER

2131850-22

5925-01-049-0030

5925 - Circuit Breakers

Honeywell Intl Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Frequency In Hertz

    400.0 all locations

  • Unpackaged Unit Weight

    5.400 ounces

  • Thread Series Designator

    unef

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Bushing Length

    0.380 inches maximum

  • Body Width

    1.875 inches maximum

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Nonturn Device Length

    0.135 inches minimum and 0.145 inches maximum

  • Nonturn Device Diameter

    0.245 inches minimum and 0.255 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Body Style

    1b multipole-single actuator type

  • Body Length

    1.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Nonturn Device Radius

    0.620 inches minimum and 0.630 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Special Handling Feature

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.375 inches

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct all locations and 0.700 maximum at 200 pct

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Terminal Type And Quantity

    6 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...