4001-002-1

Circuit Breakers

CIRCUIT BREAKER

4001-002-1

5925-01-049-3178

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and vibrationproof and moisture resistant

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac single location and 28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.672 inches minimum and 0.734 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 push-pull

  • Arc Quenching Method

    air

  • Trip Release Method

    thermal single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Unpackaged Unit Weight

    38.0 grams

  • Reset Method

    manual

  • Fragility Factor

    moderately rugged

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 single location

  • Case Material

    plastic

  • Thread Series Designator

    uns

  • Mounting Surface To Terminal End Distance

    1.919 inches minimum and 1.981 inches maximum

  • Nominal Thread Size

    0.469 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Length

    0.719 inches minimum and 0.781 inches maximum

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac single location and 1.0 amperes dc single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...