ST-228
Coils and Transformers
TRANSFORMER,POWER
ST-228
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
103.50 ac volts minimum and 126.00 ac volts maximum
-
Winding Operating Current
21.5 amperes ac nominal
-
Terminal Type And Quantity
5 screw
-
Winding Operating Voltage
12.00 ac volts nominal and 18.00 ac volts nominal
-
Winding Power Rating
387.0 volts-amperes
-
Cubic Measure
46.0 cubic inches
-
Winding Function And Quantity
1 primary and 1 secondary
-
Mounting Facility Quantity
4
-
Inclosure Type
fully inclosed
-
Winding Shielding Method
internal shield grounded to core
-
Frequency Rating
50.0 hertz minimum and 70.0 hertz maximum
-
Reliability Indicator
not established
-
Mounting Method
slot
-
Input-Output Phase Relationship
single phase to single phase
-
Mounting Slot Width
0.203 inches nominal
-
Overall Width
4.530 inches maximum
-
Overall Height
3.780 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Width
3.750 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.250 inches nominal
-
Overall Length
4.700 inches maximum