Circuit Breakers
CIRCUIT BREAKER
2567-059
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
-
Body Width
0.745 inches minimum and 0.755 inches maximum
-
Thread Series Designator
unc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Pole Quantity
1
-
Boss Height
0.125 inches minimum and 0.135 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Nominal Thread Size
0.138 inches
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
-
Body Style
single pole type
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.655 inches minimum and 1.665 inches maximum
-
Trip Release Method
magnetic-hydraulic single location
-
Terminal Type And Quantity
3 screw
-
Frequency In Hertz
60.0 single location
-
Internal Trip Release Configuration
shunt trip single location
-
Trip Release Characteristic
instantaneous single location
-
Mounting Surface To Terminal End Distance
1.875 inches minimum and 1.885 inches maximum
-
Case Material
plastic