20-812518-5
Filters and Networks
FILTER,BAND PASS
20-812518-5
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Specified Frequencies Of Discrimination Per Function
7.992 gigahertz 1st band pass and 12.008 gigahertz 1st band pass and 7.805 gigahertz 1st band pass and 12.195 gigahertz 1st band pass
-
Inclosure Type
hermetically sealed
-
Body Height
1.720 inches nominal
-
Discrimination At Specified Frequencies Per Function In Decibels
60.0 nominal 2nd band pass and 1.0 maximum 2nd band pass and 1.0 maximum 2nd band pass and 60.0 nominal 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
1.0 maximum 1st band pass and 1.0 maximum 1st band pass and 60.0 nominal 1st band pass and 60.0 nominal 1st band pass
-
Load Impedance Per Function
50.0 ohms 2nd band pass
-
Voltage Standing Wave Ratio Frequency Limits Per Function
8.0 composition b grade a pulses per second and 12.0 composition b grade a pulses per second
-
Specified Frequencies Of Discrimination Per Function
7.992 gigahertz 2nd band pass and 7.805 gigahertz 2nd band pass and 12.008 gigahertz 2nd band pass and 12.195 gigahertz 2nd band pass
-
Voltage Standing Wave Ratio Per Function
2.0 2nd band pass
-
Source Impedance Rating Per Function
50.0 ohms 1st band pass
-
Mounting Facility Type And Quantity
4 threaded hole
-
Reference Frequency Per Function
10.0 composition b grade a pulses per second
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.000 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.0 1st band pass
-
Voltage Standing Wave Ratio Frequency Limits Per Function
8.0 composition b grade a two phase to two phase and 12.0 composition b grade a two phase to two phase
-
Style Designator
rectangular terminal/terminals on three surfaces
-
Frequency Band Width Per Function
8.00 gigahertz 1st band pass and 12.00 gigahertz 1st band pass
-
Nominal Thread Size
0.138 inches
-
Source Impedance Rating Per Function
50.0 ohms 2nd band pass
-
Reference Frequency Per Function
10.0 composition b grade a two phase to two phase
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.0 2nd band pass
-
Overall Height
1.970 inches nominal
-
Mounting Facility Screw Thread Series Designator
unc
-
Body Width
1.630 inches nominal
-
Overall Length
2.390 inches nominal
-
Load Impedance Per Function
50.0 ohms 1st band pass
-
Frequency Band Width Per Function
8.00 gigahertz 2nd band pass and 12.00 gigahertz 2nd band pass
-
Body Length
1.626 inches nominal
-
Voltage Standing Wave Ratio Per Function
2.0 1st band pass