SM-C-350030

Circuit Breakers

CIRCUIT BREAKER

SM-C-350030

5925-01-049-7364

5925 - Circuit Breakers

Us Army Communications &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.630 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Inclosure Protection Type For Which Designed

    shockproof and hermetically sealed

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 1000.0 dc all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac all locations and 6.0 amperes dc all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Body Style

    multipole-single actuator type

  • Terminal Type And Quantity

    8 wire hook

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • Body Length

    1.500 inches maximum

  • Actuator Position Designation

    between pole one and two

  • Actuator Function

    trip-reset

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Trip Release Characteristic

    time delay all locations

  • Internal Trip Release Configuration

    relay trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 200 pct all locations and 12.000 maximum at 200 pct all locations

  • Body Width

    1.875 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.870 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...