Technical Characteristics
-
Winding Operating Current
800.0 milliamperes ac nominal single component single primary
-
Winding Power Rating
2.2 volts-amperes single component single secondary
-
Body Outside Diameter
0.880 inches nominal
-
Maximum Transformer Power Rating
2.2 volt-ampere single component
-
Terminal Type And Quantity
5 turret
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
2.50 ac volts nominal single component single primary
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Mounting Method
unthreaded hole single group
-
Dummy Terminal Quantity (Non-Core)
1
-
Winding Power Rating
2.0 volts-amperes single component single primary
-
Reliability Indicator
not established
-
Body Length
0.560 inches maximum
-
Frequency Rating
12.0 kilohertz nominal single component
-
Overall Length
0.760 inches maximum
-
Input-Output Phase Relationship
single phase to single phase single component
-
Maximum Operating Temp
130.0 deg celsius
-
Mounting Facility Quantity
1 single group
-
Mounting Hole Diameter
0.115 inches minimum single group and 0.120 inches maximum single group
-
Winding Operating Current
1.1 amperes ac nominal single component single secondary
-
Winding Operating Voltage
2.00 ac volts nominal single component single secondary