76-4182-01

Circuit Breakers

CIRCUIT BREAKER

76-4182-01

5925-01-050-9661

5925 - Circuit Breakers

Department Of Defense Project

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Center To Center Distance Between Terminals Parallel To Length

    7.220 inches nominal

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Inclosure Protection Type For Which Designed

    humidity resistant and moisture resistant

  • Center To Center Distance Between Terminals Parallel To Width

    2.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 24.0 dc

  • Terminal Type And Quantity

    6 screw

  • Body Length

    11.000 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Actuator Position Designation

    at pole two

  • Maximum Continuous Load Current Rating Per Pole

    400.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    42000.0 ac all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Height

    4.060 inches nominal

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole three

  • Storage Type

    general purpose warehouse

  • Circuit Protection Type

    undervoltage all locations

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.000 inches nominal

  • Mounting Facility Type And Quantity

    3 threaded hole and 4 unthreaded hole

  • Body Width

    6.000 inches nominal

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    16

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.250 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.