CF3-Z224-2W

Circuit Breakers

CIRCUIT BREAKER

CF3-Z224-2W

5925-01-051-5288

5925 - Circuit Breakers

Heinemann Electric Canada Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    6 threaded stud

  • Unpackaged Unit Weight

    2.000 pounds

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 0.600 maximum at 200 pct all locations

  • Case Material

    plastic

  • Circuit Protection Type

    overcurrent all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Body Width

    3.168 inches maximum

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac first location

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac first location

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac second location

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes dc third location

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Frequency In Hertz

    60.0 second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac second location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc third location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.781 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc third location

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac second location

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    50.0 first location or 50.0 second location or 60.0 first location

  • Center To Center Distance Between Terminals Parallel To Length

    3.547 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Height

    2.609 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Body Length

    5.800 inches nominal

  • Boss Height

    0.218 inches nominal

  • Mounting Slot Width

    0.164 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...