454-0105-004

Circuit Breakers

CIRCUIT BREAKER

454-0105-004

5925-01-052-1205

5925 - Circuit Breakers

Boeing Company The

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.630 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    sandtight and corrosion resistant and dustproof and moisture resistant and explosion proof

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac single location and 2.0 amperes dc single location

  • Frequency In Hertz

    400.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 6000.0 dc single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Unpackaged Unit Weight

    0.090 pounds

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Switch Terminal Type

    pin

  • Terminal Type And Quantity

    2 tab w/screw

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Body Length

    0.880 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Actuator Function

    trip-reset

  • Switch Current Rating And Type In Amps

    0.01 dc

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.