APL111-1RE-42-102MA

Circuit Breakers

CIRCUIT BREAKER

APL111-1RE-42-102MA

5925-01-052-5123

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Thread Pitch In Millimeters

    0.50

  • Thread Series Designator

    iso s

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    3.9 millimeters

  • Manual Actuator Type And Quantity

    3 toggle

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Body Length

    2.490 inches nominal

  • Terminal Type And Quantity

    6 threaded stud

  • Storage Type

    general purpose warehouse

  • Boss Height

    0.150 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2100.0 ac all locations

  • Body Width

    2.265 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Unpackaged Unit Weight

    12.750 ounces

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 22.000 maximum at 200 pct all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...