APL-11-1RE-52-303-MA

Circuit Breakers

CIRCUIT BREAKER

APL-11-1RE-52-303-MA

5925-01-052-5125

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc all locations

  • Pole Quantity

    2

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations

  • Actuator Position Designation

    at each pole

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Body Width

    1.500 inches maximum

  • Nominal Thread Size

    3.0 millimeters

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Thread Pitch In Millimeters

    0.50

  • Thread Series Designator

    iso s

  • Manual Actuator Type And Quantity

    2 toggle

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Unpackaged Unit Weight

    7.400 ounces

  • Terminal Type And Quantity

    4 threaded stud

  • External Actuator Linkage Arrangement

    one and two linked

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Body Style

    multipole-multiple actuator type

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and fungus resistant and salt spray proof and moisture resistant and vibration resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc all locations

  • Trip Release Method

    magnetic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...