GF-5080-50E BR
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
GF-5080-50E BR
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Overall Length
9.900 inches nominal
-
Body Length
6.900 inches nominal
-
Body Width
4.700 inches nominal
-
Body Height
3.500 inches nominal
-
Unthreaded Mounting Hole Diameter
0.205 inches nominal
-
Iii Operating Temp Range
-55.0 to 85.0 deg celsius
-
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
-
Maximum Voltage Drop Per Function
2.5 volts ac 2nd radio interference and 6.0 volts dc 2nd radio interference
-
Functional Terminal Type And Quantity
1 threaded stud input
-
Functional Terminal Type And Quantity
1 threaded stud output
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 1st radio interference and 600.0 volts dc 1st radio interference
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference and 600.0 volts dc 2nd radio interference
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 3rd radio interference and 600.0 volts dc 3rd radio interference
-
Iii Body Material
metal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Operating Current Rating Per Function In Amps
50.0 1st radio interference
-
Operating Current Rating Per Function In Amps
50.0 2nd radio interference
-
Operating Current Rating Per Function In Amps
50.0 3rd radio interference
-
Operating Current Rating Per Function In Amps
50.0 4th radio interference
-
Maximum Voltage Drop Per Function
2.5 volts ac 1st radio interference and 6.0 volts dc 1st radio interference
-
Maximum Voltage Drop Per Function
2.5 volts ac 3rd radio interference and 6.0 volts dc 3rd radio interference
-
Maximum Voltage Drop Per Function
2.5 volts ac 4th radio interference and 6.0 volts dc 4th radio interference
-
Iii Maximum Temp Rise
25.0 deg celsius
-
Inclosure Type
hermetically sealed
-
Mounting Facility Type And Quantity
6 unthreaded hole
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 4th radio interference and 600.0 volts dc 4th radio interference
-
Iii Maximum Dielectric Withstanding Dc Voltage
1.2 kilovolts at sea level
-
Iii Body Surface Treatment
tin
-
Style Designator
5 rectangular terminal/terminals on opposite surfaces