P2XAM1516MG3-80 125V60HZ

Circuit Breakers

CIRCUIT BREAKER

P2XAM1516MG3-80 125V60HZ

5925-01-054-3195

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • External Actuator Linkage Arrangement

    one and two linked

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.031 inches nominal

  • Terminal Type And Quantity

    4 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Boss Height

    0.156 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Body Width

    2.031 inches nominal

  • Arc Quenching Method

    air

  • Trip Release Method

    magnetic-hydraulic all locations

  • Maximum Continuous Load Current Rating Per Pole

    80.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Center To Center Distance Between Terminals Parallel To Width

    1.031 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Body Length

    3.719 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...