SM-A-776904-39

Circuit Breakers

CIRCUIT BREAKER

SM-A-776904-39

5925-01-054-3783

5925 - Circuit Breakers

Us Army Communications &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Arc Quenching Method

    magnetic blowout

  • Unpackaged Unit Weight

    3.600 ounces

  • Nonturn Device Diameter

    0.157 inches minimum and 0.219 inches maximum

  • Body Width

    1.250 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    90.000 maximum at 200 pct second location

  • Thread Series Designator

    unef

  • Inclosure Protection Type For Which Designed

    shock resistant and hermetically sealed and vibration resistant

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Features Provided

    high inrush protection

  • Bushing Length

    0.380 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 minimum at 200 pct second location and 0.500 minimum at 200 pct first location and 11.000 maximum at 100 pct first location

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Criticality Code Justification

    cbbl

  • Pole Quantity

    2

  • Center To Center Distance Between Terminals Parallel To Width

    0.344 inches minimum and 0.406 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac second location

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Nonturn Device Radius

    0.594 inches minimum and 0.656 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Terminal Type And Quantity

    4 wire hook

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac first location

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Body Length

    1.500 inches maximum

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...