607GKB1
Switches
SWITCH,PRESSURE
607GKB1
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Outside Diameter
0.250 inches nominal single connection
-
Contact Adjustability
deactuation point adjustable and actuation point adjustable
-
Style Designator
cylindrical
-
Err Default
err default
-
Thread Series Designator
npt single pressure connection
-
Contact Adjustment Type
external actuation point lock ring and external deactuation point lock ring
-
Width Across Flats
0.750 inches nominal
-
Contact Adjustment Range
+4.00/+22.00 actuation point pounds per square inch gage and +2.00/+20.00 deactuation point pounds per square inch gage
-
Overall Length
2.500 inches maximum
-
Frequency In Hertz
60.0 single voltage
-
Overall Diameter
0.870 inches maximum
-
Contact Load Current Rating
5.0 amperes resistive load single voltage
-
Body Length
1.850 inches nominal
-
Media For Which Designed
gas or liquid
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Pressure Connector Type
plain, threaded external single connection
-
Mounting Method
input port
-
Features Provided
electrical access port
-
Contact Voltage Rating In Volts
115.0 ac at sea level single voltage
-
Pressure Switch Type
gage
-
Terminal Type
wire lead
-
Nominal Thread Size
0.250 inches single pressure connection
-
Contact Stimulus Rating
3.00 differential point nominal pounds per square inch gage
-
Proof Pressure
300.00 pounds per square inch
-
Contact Action Stimulus
increase