581R484H04
Relays and Solenoids
RELAY,ELECTROMAGNETIC
581R484H04
Northrop Grumman Systems Corporation
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Pattern
rectangular single mounting facility
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
500.0 milliamperes ac lamp load and 500.0 milliamperes dc lamp load
-
Mounting Slot Width
0.150 inches nominal single mounting facility
-
Nonpile-Up Auxiliary Contact Arrangement
1 pole, double throw, one position momentary
-
Winding Quantity
1
-
Overall Length
1.718 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
25.0 amperes ac resistive load and 25.0 amperes dc resistive load
-
Mounting Facility Type And Quantity
4 slotted hole single mounting facility
-
Terminal Type And Quantity
11 wire hook all functions
-
Frequency In Hertz
400.0 nominal
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac motor load and 10.0 amperes dc motor load
-
Operating Voltage Rating And Type At Specified Temp
115.0 volts -80 deg fahrenheit type 4f single winding
-
Environmental Protection
hermetic and shock resistant and vibration resistant
-
Overall Height
1.015 inches nominal
-
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac resistive load and 2.0 amperes dc resistive load
-
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, momentary action
-
Main Contact Maximum Voltage Rating In Volts
200.0 ac and 28.0 dc
-
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac lamp load and 5.0 amperes dc lamp load
-
Coil Quantity
1
-
Time Delay
0.05 seconds maximum fixed release time
-
Duty Type
continuous
-
Time Delay
0.02 seconds maximum fixed operate time
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.625 inches nominal single mounting facility
-
Auxiliary Contact Maximum Voltage Rating In Volts
200.0 ac and 28.0 dc