GF55034
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
GF55034
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Body Length
4.380 inches maximum
-
Body Width
2.000 inches maximum
-
Input Terminal Manufacturer Code
03554
-
Operating Current Rating Per Function In Amps
3.0 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Mounting Facility Screw Thread Series Designator
unc
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 5th radio interference 5th function
-
Nominal Thread Size
0.112 inches
-
Operating Temp Range
+0.0/+71.0 deg celsius
-
Operating Voltage Rating And Type Per Function
28.0 volts dc 6th radio interference 6th function
-
Maximum Voltage Drop Per Function
3.0 volts ac 1st radio interference
-
Body Height
2.500 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Maximum Temp Rise
25.0 deg celsius
-
Inclosure Type
encased
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Maximum Voltage Drop Per Function
3.0 volts dc 5th radio interference
-
Operating Voltage Rating And Type Per Function
199.0 volts ac 2nd radio interference 2nd function
-
Maximum Voltage Drop Per Function
3.0 volts dc 6th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Overall Height
3.155 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
-
Operating Voltage Rating And Type Per Function
199.0 volts ac 3rd radio interference 3rd function
-
Operating Current Rating Per Function In Amps
4.5 4th radio interference
-
Operating Current Rating Per Function In Amps
1.5 1st radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Current Rating Per Function In Amps
4.5 5th radio interference
-
Body Surface Treatment
tin
-
Operating Current Rating Per Function In Amps
1.5 2nd radio interference
-
Body Material
metal
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Mounting Facility Type And Quantity
8 threaded hole
-
Operating Current Rating Per Function In Amps
3.0 3rd radio interference
-
Operating Voltage Rating And Type Per Function
26.0 volts ac 4th radio interference 4th function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Functional Terminal Type And Quantity
6 tab, solder lug output 2nd function
-
Input Terminal Identification
348-40e16-14p1
-
Maximum Voltage Drop Per Function
3.0 volts ac 2nd radio interference
-
Maximum Voltage Drop Per Function
3.0 volts ac 3rd radio interference
-
Maximum Voltage Drop Per Function
3.0 volts ac 4th radio interference
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
-
Operating Voltage Rating And Type Per Function
199.0 volts ac 1st radio interference 1st function
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.500 inches nominal