GF55034

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

GF55034

5915-01-056-3278

5915 - Filters and Networks

Spectrum Control Inc.

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Body Length

    4.380 inches maximum

  • Body Width

    2.000 inches maximum

  • Input Terminal Manufacturer Code

    03554

  • Operating Current Rating Per Function In Amps

    3.0 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Mounting Facility Screw Thread Series Designator

    unc

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 5th radio interference 5th function

  • Nominal Thread Size

    0.112 inches

  • Operating Temp Range

    +0.0/+71.0 deg celsius

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 6th radio interference 6th function

  • Maximum Voltage Drop Per Function

    3.0 volts ac 1st radio interference

  • Body Height

    2.500 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Inclosure Type

    encased

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Maximum Voltage Drop Per Function

    3.0 volts dc 5th radio interference

  • Operating Voltage Rating And Type Per Function

    199.0 volts ac 2nd radio interference 2nd function

  • Maximum Voltage Drop Per Function

    3.0 volts dc 6th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Overall Height

    3.155 inches maximum

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Voltage Rating And Type Per Function

    199.0 volts ac 3rd radio interference 3rd function

  • Operating Current Rating Per Function In Amps

    4.5 4th radio interference

  • Operating Current Rating Per Function In Amps

    1.5 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Operating Current Rating Per Function In Amps

    4.5 5th radio interference

  • Body Surface Treatment

    tin

  • Operating Current Rating Per Function In Amps

    1.5 2nd radio interference

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Operating Current Rating Per Function In Amps

    3.0 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    26.0 volts ac 4th radio interference 4th function

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    6 tab, solder lug output 2nd function

  • Input Terminal Identification

    348-40e16-14p1

  • Maximum Voltage Drop Per Function

    3.0 volts ac 2nd radio interference

  • Maximum Voltage Drop Per Function

    3.0 volts ac 3rd radio interference

  • Maximum Voltage Drop Per Function

    3.0 volts ac 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Operating Voltage Rating And Type Per Function

    199.0 volts ac 1st radio interference 1st function

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.500 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...