AFD24-22-55PN

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

AFD24-22-55PN

5915-01-056-4690

5915 - Filters and Networks

Deutsch Engineered Connecting

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 2nd radio interference 2nd function and 800.0 volts dc 2nd radio interference 2nd function

  • Functional Terminal Type And Quantity

    55 friction w/grounding strap and pin input-output

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Body Material

    aluminum

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 1st radio interference 1st function and 800.0 volts dc 1st radio interference 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Precious Material And Location

    contact surfaces silver

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Mounting Facility Screw Thread Series Designator

    unef

  • Features Provided

    moisture resistant and shock resistant

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 4th radio interference 4th function and 800.0 volts dc 4th radio interference 4th function

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Body Surface Treatment

    cadmium

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 6th radio interference 6th function and 800.0 volts dc 6th radio interference 6th function

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 3rd radio interference 3rd function and 800.0 volts dc 3rd radio interference 3rd function

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Overall Height

    1.922 inches minimum and 1.954 inches maximum

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    filter connector

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Overall Width

    1.922 inches minimum and 1.954 inches maximum

  • Nominal Thread Size

    1.500 inches

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 5th radio interference 5th function and 800.0 volts dc 5th radio interference 5th function

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Special Features

    fifty-five filtered functions

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Overall Length

    2.264 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Precious Material

    silver

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...