861804
Coils and Transformers
TRANSFORMER,POWER
861804
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
10.50 ac volts nominal single component 3rd secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
20.00 ac volts nominal single component 2nd secondary
-
Mounting Facility Quantity
1 single group
-
Terminal Type And Quantity
12 turret
-
Winding Function And Quantity
1 primary single component and 3 secondary single component
-
Frequency Rating
25.0 kilohertz nominal single component
-
Body Length
0.800 inches nominal
-
Winding Operating Voltage
4.20 ac volts nominal single component 1st secondary
-
Winding Operating Current
500.0 milliamperes ac maximum single component 1st secondary
-
Winding Operating Current
10.0 amperes ac maximum single component 2nd secondary
-
Winding Operating Current
10.0 amperes ac maximum single component 3rd secondary
-
Inclosure Type
fully inclosed
-
Mounting Hole Diameter
0.139 inches minimum single group and 0.145 inches maximum single group
-
Mounting Method
unthreaded hole single group
-
Reliability Indicator
not established
-
Body Outside Diameter
1.500 inches maximum
-
Winding Operating Voltage
135.00 ac volts nominal single component single primary