JL-1-A2-1-2
Circuit Breakers
CIRCUIT BREAKER
JL-1-A2-1-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
2.000 inches nominal
-
Case Material
plastic
-
Pole Quantity
1
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac
-
Trip Release Method
magnetic-hydraulic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 push-pull
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Switch Terminal Type
quick disconnect,male
-
Trip Release Characteristic
time delay
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Auxiliary Switch Function And Quantity
1 alarm
-
Switch Location And Position Designation
internal at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 minimum at 200 pct and 20.000 maximum at 200 pct
-
Switch Current Rating And Type In Amps
1.0 ac and 0.5 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Frequency In Hertz
60.0
-
Terminal Type And Quantity
2 quick disconnect,male
-
Overall Height
0.750 inches nominal
-
Overall Width
1.700 inches nominal
-
Switch Contact Arrangement
single pole,double throw
-
Mounting Facility Type And Quantity
2 terminal
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac
-
Circuit Protection Type
overcurrent