AM3-Z179-1-50
Circuit Breakers
CIRCUIT BREAKER
AM3-Z179-1-50
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
2.500 inches nominal
-
Body Width
2.200 inches minimum and 2.280 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Fragility Factor
moderately rugged
-
Boss Height
0.140 inches nominal
-
Pole Quantity
3
-
Arc Quenching Method
magnetic blowout
-
Special Handling Feature
magnetic
-
Body Style
8c multipole-multiple actuator type
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Mounting Surface To Terminal End Distance
2.409 inches minimum and 2.533 inches maximum
-
Mounting Facility Type And Quantity
6 threaded hole
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac first location
-
Operating Voltage Type And Rating Per Pole In Volts
12.0 dc third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc third location
-
Circuit Protection Type
overcurrent second location
-
Circuit Protection Type
undervoltage third location
-
Trip Release Characteristic
time delay first location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct first location and 2.000 maximum at 200 pct
-
Frequency In Hertz
400.0 first location
-
Thread Series Designator
unc
-
Terminal Type And Quantity
6 threaded stud
-
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac second location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
-
Circuit Protection Type
overcurrent first location
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
instantaneous third location
-
Trip Release Characteristic
time delay second location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct second location and 2.000 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Frequency In Hertz
400.0 second location
-
Unpackaged Unit Weight
9.500 ounces