3-20113
Coils and Transformers
TRANSFORMER,POWER
3-20113
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Current
2.0 amperes dc nominal single component 4th secondary
-
Special Features
one primary winding; five secondary windings
-
Winding Operating Voltage
14.30 ac volts nominal single component 1st secondary
-
Overall Height
5.344 inches minimum and 5.406 inches maximum
-
Mounting Method
slot all groupings
-
Body Length
3.800 inches nominal
-
Body Width
3.015 inches maximum
-
Winding Operating Current
9.1 amperes dc nominal single component 2nd secondary
-
Winding Operating Voltage
14.30 ac volts nominal single component 2nd secondary
-
Winding Operating Current
5.9 amperes dc nominal single component 3rd secondary
-
Winding Operating Voltage
14.30 ac volts nominal single component 3rd secondary
-
Terminal Type And Quantity
20 tab, solder lug
-
Transformer Winding Connection Type
wye-delta
-
Maximum Operating Temp
155.0 deg celsius
-
Inclosure Type
fully inclosed
-
Winding Operating Current
15.5 amperes dc nominal single component 1st secondary
-
Input-Output Phase Relationship
three phase to three phase single component
-
Mounting Slot Width
0.156 inches nominal all groupings
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.234 inches minimum single mounting facility all center groupings and 3.266 inches maximum single mounting facility all center groupings
-
Unpackaged Unit Weight (Non-Core)
8.000 pounds
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.320 inches minimum single mounting facility all center groupings and 2.440 inches maximum single mounting facility all center groupings
-
Winding Operating Voltage
20.30 ac volts nominal single component 4th secondary
-
Mounting Facility Quantity
4 all groupings
-
Winding Function And Quantity
1 primary single component and 5 secondary single component