Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    800.0 ac single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Internal Trip Release Configuration

    shunt trip single location

  • Terminal Type And Quantity

    3 tab w/screw

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Unpackaged Unit Weight

    2.000 ounces

  • Mounting Surface To Terminal End Distance

    1.669 inches nominal

  • Nominal Thread Size

    0.469 inches

  • Body Length

    1.781 inches nominal

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Bushing Length

    0.250 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    1.341 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.070 minimum at 200 pct single location and 1.750 maximum at 200 pct single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Pole Quantity

    1

  • Body Width

    0.656 inches nominal

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...