56-14-001
Coils and Transformers
TRANSFORMER,POWER
56-14-001
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
47.0 hertz minimum and 62.0 hertz maximum
-
Input-Output Phase Relationship
single phase to single phase
-
Winding Function And Quantity
2 primary and 4 secondary
-
Thread Quantity Per Inch
32
-
Winding Tap Location
center tap
-
Winding Operating Voltage
13.00 ac volts nominal
-
Special Features
primaries can be parallel wired for 230 volt input
-
Terminal Type And Quantity
12 tab,solder lug
-
Winding Shielding Method
internal shield grounded to inclosure
-
Body Length
3.125 inches nominal
-
Body Width
2.938 inches nominal
-
Body Height
4.125 inches nominal
-
Inclosure Type
open
-
Mounting Facility Quantity
4
-
Mounting Method
threaded hole
-
Nominal Thread Size
0.190 inches
-
Winding Operating Voltage
115.00 ac volts nominal
-
Winding Operating Voltage
20.00 ac volts nominal
-
Winding Operating Voltage
37.00 ac volts nominal
-
Winding Operating Voltage
57.00 ac volts nominal
-
Thread Series Designator
unf
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.000 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal
-
Thread Class
3a