APL111-1-41-153-MA

Circuit Breakers

CIRCUIT BREAKER

APL111-1-41-153-MA

5925-01-059-9773

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    63.25 millimeters nominal

  • Body Width

    57.53 millimeters maximum

  • Center To Center Distance Between Terminals Parallel To Length

    49.28 millimeters nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    52.32 millimeters nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    19.05 millimeters nominal

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    3.0 millimeters

  • Thread Pitch In Millimeters

    0.50

  • Inclosure Protection Type For Which Designed

    corrosion resistant and fungus resistant and moisture resistant and shockproof and vibrationproof

  • Thread Series Designator

    iso s

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    19.05 millimeters nominal

  • Boss Height

    3.81 millimeters nominal

  • Mounting Surface To Terminal End Distance

    63.66 millimeters maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded stud

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Ultimate Trip Time Per Pole In Seconds

    0.600 minimum and 3.000 maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct and 2.000 maximum at 200 pct

  • Thread Tolerance Class

    any acceptable

  • Frequency In Hertz

    400.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...