219-3-1-63F-3-9-60A

Circuit Breakers

CIRCUIT BREAKER

219-3-1-63F-3-9-60A

5925-01-059-9782

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    3.0 millimeters

  • Frequency In Hertz

    60.0

  • Thread Series Designator

    iso s

  • Body Length

    5.800 inches nominal

  • Body Width

    3.108 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Boss Height

    0.220 inches nominal

  • Mounting Surface To Terminal End Distance

    3.550 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Features Provided

    high inrush protection

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Thread Pitch In Millimeters

    0.50

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 130.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Unpackaged Unit Weight

    2.000 pounds

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac

  • Circuit Protection Type

    overcurrent

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...