129240-1
Filters and Networks
FILTER,BAND PASS
129240-1
Cubic Defense Applications Inc.
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
5.000 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 1st band pass .
-
Voltage Standing Wave Ratio Per Function
1.25 1st band pass .
-
Insertion Loss At Reference Frequency Per Function In Decibels
1.5 1st band pass .
-
Functional Terminal Type And Quantity
1 connector, receptacle input .
-
Functional Terminal Type And Quantity
1 connector, receptacle output .
-
~1
ertz 2nd band pass and 1.885 gigahertz 2nd band pass .
-
Frequency Band Width Per Function
1.7985 gigahertz 2nd band pass and 1.8365 gigahertz 2nd band pass .
-
~1
d pass and 50.0 minimum 1st band pass .
-
Discrimination At Specified Frequencies Per Function In Decibels
25.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 3.0 maximum 2nd ban
-
Voltage Standing Wave Ratio Frequency Limits Per Function
1.7985 gigahertz 2nd band pass and 1.8365 gigahertz 2nd band pass .
-
Body Length
6.600 inches nominal
-
Body Height
1.800 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
6.420 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
4.426 inches nominal
-
Reference Frequency Per Function
1.8175 gigahertz 1st band pass .
-
Reference Frequency Per Function
1.8175 gigahertz 2nd band pass .
-
Source Impedance Rating Per Function
50.0 ohms 2nd band pass .
-
Load Impedance Per Function
50.0 ohms 1st band pass .
-
Load Impedance Per Function
50.0 ohms 2nd band pass .
-
Voltage Standing Wave Ratio Per Function
1.25 2nd band pass .
-
Mounting Facility Screw Thread Series Designator
unf
-
Inclosure Type
encased
-
Mounting Facility Type And Quantity
4 threaded hole
-
Insertion Loss At Reference Frequency Per Function In Decibels
0.5 2nd band pass .
-
~1
hertz 1st band pass and 1.84 gigahertz 1st band pass .
-
Specified Frequencies Of Discrimination Per Function
1.75 gigahertz 2nd band pass and 1.7985 gigahertz 2nd band pass and 1.8365 gigah
-
Specified Frequencies Of Discrimination Per Function
1.779 gigahertz 1st band pass and 1.7985 gigahertz 1st band pass and 1.8365 giga
-
Nominal Thread Size
0.190 inches
-
Frequency Band Width Per Function
1.7985 gigahertz 1st band pass and 1.8365 gigahertz 1st band pass .
-
~1
d pass and 25.0 minimum 2nd band pass .
-
Discrimination At Specified Frequencies Per Function In Decibels
50.0 minimum 1st band pass and 3.0 maximum 1st band pass and 3.0 maximum 1st ban
-
Voltage Standing Wave Ratio Frequency Limits Per Function
1.7985 gigahertz 1st band pass and 1.8365 gigahertz 1st band pass .
-
Style Designator
5 rectangular terminal/terminals on opposite surfaces