AP112-2066-5

Circuit Breakers

CIRCUIT BREAKER

AP112-2066-5

5925-01-062-4462

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.250 inches nominal

  • Bushing Length

    0.380 inches maximum

  • Terminal Type And Quantity

    6 wire hook

  • Thread Series Designator

    unef

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • Ultimate Trip Time Per Pole In Seconds

    3.000 minimum all locations

  • Trip Release Duty Cycle

    continuous all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.500 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Body Style

    multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Actuator Position Designation

    at pole two

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    1.875 inches maximum

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.001 nominal at 1000 pct all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...