6090958-2

Filters and Networks

FILTER,RADIO FREQUENCY INTERFERENCE

6090958-2

5915-01-063-7133

5915 - Filters and Networks

Lockheed Martin Corporation

FILTER,RADIO FREQUENCY INTERFERENCE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Input Terminal Identification

    ms3106a28-21p

  • Input Terminal Manufacturer Code

    81349

  • Maximum Voltage Drop Per Function

    200.0 millivolts dc 6th radio interference .

  • Maximum Voltage Drop Per Function

    200.0 millivolts dc 5th radio interference .

  • Maximum Voltage Drop Per Function

    200.0 millivolts dc 4th radio interference .

  • Maximum Voltage Drop Per Function

    1.15 volts ac 3rd radio interference .

  • Maximum Voltage Drop Per Function

    1.15 volts ac 1st radio interference .

  • Operating Current Rating Per Function In Amps

    1.5 6th radio interference .

  • Operating Current Rating Per Function In Amps

    1.25 3rd radio interference .

  • Operating Current Rating Per Function In Amps

    1.25 1st radio interference .

  • Load Impedance Per Function

    50.0 ohms 6th radio interference .

  • Load Impedance Per Function

    50.0 ohms 5th radio interference .

  • Load Impedance Per Function

    50.0 ohms 4th radio interference .

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference .

  • Load Impedance Per Function

    50.0 ohms 1st radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference .

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    5.000 inches nominal

  • Vibration Resistance Range In Hertz

    4.0/ 33.0

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    6.000 inches nominal

  • Overall Height

    6.000 inches nominal

  • Inclosure Type

    encased

  • Output Terminal Identification

    ms3126e-14-19s

  • Output Terminal Manufacturer Code

    81349

  • Body Surface Treatment

    tin

  • Body Material

    metal

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 3rd radio interference .

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 1st radio interference .

  • Mounting Facility Screw Thread Series Designator

    unf

  • Maximum Temp Rise

    25.0 deg celsius

  • Maximum Voltage Drop Per Function

    1.15 volts ac 2nd radio interference .

  • Operating Current Rating Per Function In Amps

    2.0 5th radio interference .

  • Operating Current Rating Per Function In Amps

    1.25 2nd radio interference .

  • Operating Current Rating Per Function In Amps

    1.0 4th radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference .

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference .

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference .

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference .

  • Operating Temp Range

    -54.0/+85.0 deg celsius

  • Body Width

    6.000 inches nominal

  • Body Length

    7.000 inches nominal

  • Overall Length

    13.313 inches minimum and 13.687 inches maximum

  • Specification/Standard Data

    81349-mil-f-15733 government specification

  • Style Designator

    30 rectangular terminal/terminals on opposite surfaces

  • Special Features

    11 functions

  • Maximum Dielectric Withstanding Dc Voltage

    400.0 volts at sea level

  • Nominal Thread Size

    0.250 inches

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 6th radio interference .

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 5th radio interference .

  • Operating Voltage Rating And Type Per Function

    28.0 volts dc 4th radio interference .

  • Operating Voltage Rating And Type Per Function

    115.0 volts ac 2nd radio interference .

  • Functional Terminal Type And Quantity

    1 connector, plug output .

  • Functional Terminal Type And Quantity

    1 connector, plug input .

  • Mounting Facility Type And Quantity

    4 captive screws

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...