AM3-A3-10-2
Circuit Breakers
CIRCUIT BREAKER
AM3-A3-10-2
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 maximum at 200 pct all locations and 2.000 minimum at 200 pct all locations and 0.300 minimum at 400 pct all locations and 0.600 minimum at 300 pct all locations and 2.000 maximum at 400 pct all locations and 5.000 maximum at 300 pct all locations
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Boss Height
0.130 inches minimum and 0.150 inches maximum
-
Case Material
plastic
-
Terminal Type And Quantity
6 threaded stud
-
~1
and 0.005 minimum at 1000 pct all locations a
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Mounting Surface To Terminal End Distance
2.331 inches minimum and 2.492 inches maximum
-
Actuator Position Designation
at each pole
-
Thread Series Designator
unc
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
3
-
Fragility Factor
moderately rugged
-
Ultimate Trip Time Per Pole In Seconds
10.000 minimum all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
50.0 all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Nominal Thread Size
0.138 inches
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
-
Mounting Facility Type And Quantity
6 threaded hole
-
Unpackaged Unit Weight
12.750 ounces
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Body Width
2.240 inches minimum and 2.260 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Body Style
multipole-multiple actuator type
-
Trip Release Method
magnetic-hydraulic all locations
-
Thread Quantity Per Inch
32