Technical Characteristics

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Mounting Surface To Terminal End Distance

    2.800 inches maximum

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Switch Terminal Type

    tab, solder lug

  • Trip Release Method

    magnetic single location

  • Body Width

    0.730 inches minimum and 0.780 inches maximum

  • Fragility Factor

    moderately rugged

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct single location and 8.000 maximum at 200 pct single location

  • Specification/Standard Data

    81349-mil-c-55629/2 government specification

  • ~1

    data on certain environmental and performanc

  • Terminal Type And Quantity

    2 threaded stud

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Boss Height

    0.109 inches minimum and 0.171 inches maximum

  • Body Length

    2.510 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Style

    single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes dc single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...