203-2-2-61-252-4-1-1

Circuit Breakers

CIRCUIT BREAKER

203-2-2-61-252-4-1-1

5925-01-066-4903

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 28.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac single location

  • Switch Current Rating And Type In Amps

    5.0 ac and 5.0 dc

  • Body Length

    2.000 inches nominal

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Switch Terminal Type

    turret

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Mounting Facility Type And Quantity

    1 clip

  • Body Width

    0.920 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Frequency In Hertz

    60.0 single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Height

    1.545 inches nominal

  • Body Style

    single pole type

  • Special Features

    handle equipped with internally mtd light emitting diode

  • Terminal Type And Quantity

    2 tab, solder lug

  • Boss Height

    0.125 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Switch Contact Arrangement

    single pole, double throw

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.050 minimum at 200 pct single location and 0.020 minimum at 400 pct single location and 1.000 maximum at 200 pct single location and 0.250 maximum at 400 pct single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.