MS26574-2-1-2

Circuit Breakers

CIRCUIT BREAKER

MS26574-2-1-2

5925-01-067-2924

5925 - Circuit Breakers

Military Standards

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Switch Location And Position Designation

    external at pole one

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Body Length

    0.749 inches minimum and 0.780 inches maximum

  • Switch Current Rating And Type In Amps

    2.5 ac and 2.5 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 20.000 maximum at 200 pct single location

  • Case Material

    metal

  • Pole Quantity

    1

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 28.0 dc

  • Manual Actuator Type And Quantity

    1 push-pull

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    thermal single location

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac single location and 2.5 amperes dc single location

  • Circuit Protection Type

    overcurrent single location

  • Nominal Thread Size

    0.438 inches

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Terminal Type And Quantity

    2 screw

  • ~1

    data on certain environmental and performance

  • Mounting Surface To Terminal End Distance

    1.494 inches minimum and 1.525 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Specification/Standard Data

    96906-ms26574 government specification

  • Switch Contact Arrangement

    single pole, single throw, normally closed

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Body Width

    0.531 inches minimum and 0.593 inches maximum

  • Bushing Length

    0.219 inches minimum and 0.281 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 ac single location and 100.0 dc single location

  • Thread Series Designator

    un

  • Center To Center Distance Between Terminals Parallel To Length

    0.562 inches minimum and 0.624 inches maximum

  • Auxiliary Switch Function And Quantity

    1 control

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...