AS58091

Circuit Breakers

CIRCUIT BREAKER

AS58091

5925-01-067-2927

5925 - Circuit Breakers

Society Of Automotive Engineers Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.750 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac single location and 30.0 dc single location

  • Bushing Length

    0.220 inches minimum and 0.280 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Center To Center Distance Between Terminals Parallel To Length

    1.160 inches minimum and 1.220 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Unpackaged Unit Weight

    0.250 pounds

  • Pole Quantity

    1

  • Case Material

    metal

  • Specification/Standard Data

    96906-ms25244 government standard

  • Body Length

    2.189 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location and 6000.0 dc single location

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Terminal Type And Quantity

    2 tab w/screw

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.796 inches minimum and 1.828 inches maximum

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...