3522 500 26382

Circuit Breakers

CIRCUIT BREAKER

3522 500 26382

5925-01-070-7436

5925 - Circuit Breakers

Thales Nederland

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Specification/Standard Data

    81349-mil-c-39019/2 government specification

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Body Length

    1.562 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Frequency In Hertz

    400.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Body Style

    single pole type

  • Body Width

    0.625 inches maximum

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct single location

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Unpackaged Unit Weight

    50.0 grams

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location and 500.0 dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 50.0 dc single location

  • Bushing Length

    0.380 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Circuit Protection Type

    overcurrent single location

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac single location and 7.0 amperes dc single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Special Handling Feature

    magnetic

  • Switch Terminal Type

    tab, solder lug

  • Terminal Type And Quantity

    2 wire hook

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...