JC2-A3A3-A-2-2

Circuit Breakers

CIRCUIT BREAKER

JC2-A3A3-A-2-2

5925-01-070-8448

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.098 inches minimum and

  • Bushing Length

    0.162 inches maximum

  • Body Length

    1.968 inches minimum and

  • Body Width

    1.532 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.782 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.718 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.782 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.898 inches minimum and

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    22.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    4 quick disconnect, male

  • Body Style

    1c multipole-multiple actuator type

  • Body Length

    2.032 inches maximum

  • Body Width

    1.468 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    1.528 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    1.592 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.718 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.628 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.692 inches maximum

  • Mounting Surface To Terminal End Distance

    1.962 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one and two linked

  • Frequency In Hertz

    60.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...