AP12-4613-2

Circuit Breakers

CIRCUIT BREAKER

AP12-4613-2

5925-01-071-1747

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    50.0 milliamperes ac second location

  • Bushing Length

    0.380 inches maximum

  • Thread Series Designator

    unef

  • Body Width

    1.250 inches maximum

  • Unpackaged Unit Weight

    3.600 ounces

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    vibration resistant and hermetically sealed and shock resistant

  • Actuator Position Designation

    between pole one and two

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Pole Quantity

    2

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Nonturn Device Diameter

    0.250 inches nominal

  • Fragility Factor

    moderately rugged

  • Body Length

    1.500 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Nonturn Device Radius

    0.625 inches nominal

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac first location

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Terminal Type And Quantity

    4 wire hook

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Nonturn Device Length

    0.140 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 11.000 maximum at 200 pct all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...