MIL-T-23648/19

Resistors

RESISTOR,THERMAL

MIL-T-23648/19

5905-01-072-3376

5905 - Resistors

Military Specifications

RESISTOR,THERMAL

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-t-23648/19 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general

  • Zero Power Resistance At Specified Temp

    47.2 ohms 6th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -14.0/+14.0 4th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -14.0/+14.0 2nd resistance-temperature point

  • Reliability Indicator

    not established

  • Terminal Type And Quantity

    2 wire lead

  • Style Designator

    rod

  • Ambient Temp At Full Rated Power

    25.0 deg celsius

  • Maximum Operating Temp

    125.0 deg celsius

  • Zero Power Resistance At Specified Temp

    36.4 ohms 4th resistance-temperature point

  • Power Dissipation Constant In Milliwatts Per Deg Celsius

    2.5

  • Zero Power Resistance

    27.000 ohms

  • Zero Power Resistance At Specified Temp

    31.3 ohms 3rd resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -20.0/+20.0 6th resistance-temperature point

  • Reference Temp In Deg Celsius

    25.0

  • Zero Power Resistance At Specified Temp

    41.7 ohms 5th resistance-temperature point

  • Body Outside Diameter

    0.100 inches nominal

  • Zero Power Resistance At Specified Temp

    16.6 ohms 1st resistance-temperature point

  • Terminal Diameter

    0.020 inches nominal

  • Temp Points For Resistance Readings At Zero Power

    75.0 deg celsius 4th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -20.0/+20.0 1st resistance-temperature point

  • Maximum Power Dissipation Rating

    0.25 watts

  • Zero Power Resistance At Specified Temp

    21.3 ohms 2nd resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    50.0 deg celsius 3rd resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    -15.0 deg celsius 2nd resistance-temperature point

  • Temp Points For Resistance Readings At Zero Power

    125.0 deg celsius 6th resistance-temperature point

  • Thermal Time Constant In Seconds

    60.0

  • Zero Power Resistance Tolerance In Percent At Reference Temp

    -10.0/+10.0

  • Body Length

    0.285 inches nominal

  • Temp Points For Resistance Readings At Zero Power

    -55.0 deg celsius 1st resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -12.0/+12.0 3rd resistance-temperature point

  • Terminal Length

    1.200 inches minimum

  • Temp Points For Resistance Readings At Zero Power

    100.0 deg celsius 5th resistance-temperature point

  • Resistance Tolerance At A Specified Temp In Percent

    -17.0/+17.0 5th resistance-temperature point

  • Inclosure Type

    hermetically sealed

  • ~1

    type data on certain environmental and perform

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...