TF3247
Coils and Transformers
TRANSFORMER,POWER
TF3247
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Outside Diameter
1.250 inches maximum
-
Maximum Operating Temp
85.0 deg celsius
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary and 1 secondary single component
-
Test Data Document
80063-sm-a-878713 drawing
-
Body Length
0.480 inches maximum
-
Mounting Method
terminal single group
-
Features Provided
color coded terminal and tinned wire leads
-
Winding Operating Current
1.0 amperes ac maximum single component single secondary
-
~1
y
-
Winding Operating Voltage
0.19 ac volts minimum and 0.20 ac volts maximum single component single secondar
-
Winding Operating Voltage
3.96 ac volts minimum and 4.04 ac volts maximum single component single primary
-
Terminal Type And Quantity
4 wire lead
-
Reliability Indicator
not established
-
Frequency Rating
9.5 kilohertz minimum and 10.5 kilohertz maximum single component