GS835HV7-2-8N
Switches
SWITCH,ROTARY
GS835HV7-2-8N
Northrop Grumman Systems Corporation
SWITCH,ROTARY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Load Current Rating
500.0 milliamperes resistive load lowest dc voltage rating at sea level and 50.0 milliamperes inductive load lowest dc voltage rating at sea level
-
Nominal Thread Size
0.138 inches 2nd mounting facility
-
Contact Switching Action
makes before breaks 1st section rear
-
Switch Actuator Indexing Position Quantity
8 single actuator
-
Shaft Flat/Slot Angular Location
0.0 degrees from contact position 1 single actuator
-
Precious Material And Location
current carrying parts surfaces gold
-
Switch Actuator Stop Device Type
fixed stop single actuator
-
Detent Rotational Torque Range
+1.500/+13.000 inch-pounds single actuator
-
Thread Quantity Per Inch
32 2nd mounting facility
-
Shaft Diameter
0.250 inches nominal single actuator
-
Contact Switching Action
breaks before makes 2nd section rear
-
Thread Series Designator
unef 1st mounting facility
-
Thread Class
2a 1st mounting facility
-
Flat Height
0.218 inches nominal single actuator
-
Switch Actuator Positioning Increment
22.5 degrees single actuator
-
Mounting Method
threaded bushing 1st mounting facility
-
Err Default
err default
-
Mounting Method
threaded hole 2nd mounting facility
-
Contact Switching Action
breaks before makes 3rd section rear
-
Mounting Facility Pattern
two position in-line 2nd mounting facility
-
First Flat Length
0.250 inches nominal single actuator
-
Pole Quantity
2 each section front
-
Throw Quantity
8 each section rear
-
Shaft Type
round, flatted single actuator
-
Individual Section Quantity
7
-
Precious Material
gold
-
Contact Switching Action
breaks before makes 4th section rear
-
Rotor Through Connection Quantity
2 each section
-
Contact Voltage Rating In Volts
300.0 highest dc voltage rating at sea level
-
Shaft Length
0.250 inches nominal single actuator
-
Contact Switching Action
breaks before makes 5th section rear
-
Thread Series Designator
unc 2nd mounting facility
-
Longest Horizontal Distance Between Mounting Centers
1.375 inches nominal 2nd mounting facility
-
Terminal Type
tab, solder lug
-
Operating Temp Range
-65.0/+125.0 deg celsius
-
Contact Switching Action
breaks before makes 6th section rear
-
Overall Length
5.480 inches nominal
-
Switch Contact Basic Design
nonpile-up symmetrical
-
Style Designator
square wafer, panel mount
-
Nominal Thread Size
0.375 inches 1st mounting facility
-
Thread Class
2b 2nd mounting facility
-
Contact Switching Action
breaks before makes 7th section rear
-
Contact Voltage Rating In Volts
30.0 lowest dc voltage rating at sea level
-
Contact Load Current Rating
50.0 milliamperes resistive load highest dc voltage rating at sea level